电感耦合等离子体原子发射光谱法用于不锈钢保温杯浸出液中金属离子的测定
倪英哲, 章子恒, 胡然, 皮夫, 高雨辰, 曹秋娥, 周川华

ICP-AES Determination of Metal Ions in the Leaching Solution of Stainless Steel Thermos Cups
Yingzhe Ni, Ziheng Zhang, Ran Hu, Fu Pi, Yuchen Gao, Qiue Cao, Chuanhua Zhou
表3 实验测定数据与国家标准对比
样品处理方式浸泡方式Cd(μg?mL?1)Cr(μg?mL?1)Mn(μg?mL?1)Ni(μg?mL?1)Pb(μg?mL?1)Zn(μg?mL?1)
GB5749–2006国家饮用水标准0.0050.050.10.020.011.0
1号样品未处理4%醋酸0.00000.02210.02990.00190.00220.0544
可乐?0.00030.00650.00800.0009?0.0014?0.0261
2号样品未处理4%醋酸?0.00010.03590.1328
↑
0.0059?0.00210.0041
可乐?0.00010.00280.00190.0003?0.0009?0.0272
3号样品餐叉刮蹭4%醋酸?0.00010.01800.1716
↑
0.0028?0.00030.0046
可乐?0.00020.00700.02380.0428
↑
?0.0007?0.0265
4号样品砂纸摩擦4%醋酸0.00000.00950.1074
↑
0.0022?0.0022?0.0115
可乐?0.00030.00320.00410.0001?0.0014?0.0270
5号样品钢丝球摩擦4%醋酸0.00010.2052
↑
0.01570.0022?0.0014?0.0040
可乐?0.00030.00680.00720.0125?0.0014?0.0283
6号样品未处理4%醋酸0.00010.00270.00060.00240.00000.0360