凝固点降低法测定摩尔质量实验装置的改进和应用
|
|
黄钟明, 梁沁睿, 黄宛鸿, 荣勤丰, 董家新
|
Improvement and Application of the Device for Determination of Molar Mass by Freezing Point Depression
|
|
Zhongming Huang, Qinrui Liang, Wanhong Huang, Qinfeng Rong, Jiaxin Dong
|
|
表3 三种仪器测量尿素、蔗糖和萘的摩尔质量结果
|
| |
|
| 仪器 | WA /g | WB /g | ∆Tf /K | M /(g∙mol−1) | M理论/(g∙mol−1) | 相对误差/% | | 尿素 | | 仪器A | 100.60 | 1.6028 | 0.449 ± 0.029 | 66.5 ± 4.3 | 60.06 | 10.7 | | 仪器B | 103.75 | 2.2205 | 0.617 ± 0.017 | 64.3 ± 1.8 | 60.06 | 7.06 | | 改进仪器 | 201.06 | 3.2092 | 0.492 ± 0.002 | 60.1 ± 0.2 | 60.06 | 0.07 | | 蔗糖 | | 仪器A | 100.48 | 9.2364 | 0.454 ± 0.020 | 375 ± 17 | 342.30 | 9.55 | | 仪器B | 104.00 | 8.2495 | 0.445 ± 0.053 | 330 ± 39 | 342.30 | −3.59 | | 改进仪器 | 202.04 | 18.5200 | 0.478 ± 0.002 | 355 ± 1 | 342.30 | 3.71 | | 萘 | | 仪器A | 100.40 | 0.3072 | 0.604 ± 0.007 | 102 ± 1 | 128.17 | −20.4 | | 仪器B | 101.10 | 0.3210 | 0.618 ± 0.050 | 104 ± 8 | 128.17 | −18.9 | | 改进仪器 | 200.08 | 0.6412 | 0.517 ± 0.002 | 125 ± 1 | 128.17 | −2.47 |
|
|
|