基于ZIF-8/WCNT电化学传感器检测呋喃西林在实验教学中的设计与探索
郭美洁, 麻力文, 樊运康, 秦建芳, 张艳清, 杨海英

Design and Evaluation of a ZIF-8/WCNT-Based Electrochemical Sensor for Nitrofurazone Determination in Laboratory Teaching
Meijie Guo, Liwen Ma, Yunkang Fan, Jianfang Qin, Yanqing Zhang, Haiying Yang
表3 ZIF-8/WCNT/GCE电化学传感器对呋喃西林溶液的检测和回收实验结果
标示值/(μmol∙L−1) a测定值/(μmol∙L−1) b加入量/(μmol∙L−1)测定量/(μmol∙L−1)回收率/%
10.010.1 (±3.20%)10.09.8598.5
20.020.6103.0