大学化学, 2022, 37(12): 2112039-0 doi: 10.3866/PKU.DXHX202112039

化学实验

分光光度法测定铬黑T解离常数实验设计

孙瑞卿,, 许紫婷, 陈珠灵, 林佳丽

Experimental Design on the Determination of Dissociation Constants of Eriochrome Black T by Spectrophotometry

Sun Ruiqing,, Xu Ziting, Chen Zhuling, Lin Jiali

通讯作者: 孙瑞卿, Email: 1031598981@qq.com

收稿日期: 2021-12-14   接受日期: 2022-02-22  

Received: 2021-12-14   Accepted: 2022-02-22  

Abstract

This work aims to provide an approach to determine the dissociation constant (pKa) of Eriochrome Black T by using UV-Visible spectrophotometry. The absorbance of Eriochrome Black T was measured at different pH and the data was fitted by ORIGIN with specific function model. Based on the obtained formula, the three pKa of Eriochrome Black T can be calculated, respectively. This method is highly efficient, accurate, and easy to operate. It can also serve as an expansion for the undergraduates' chemistry laboratory, which can help cultivate the students' comprehensive ability of experimental design, data processing, and model derivation.

Keywords: Dissociation constant ; Ultraviolet-visible spectrophotometry ; Eriochrome Black T

PDF (699KB) 元数据 多维度评价 相关文章 导出 EndNote| Ris| Bibtex  收藏本文

本文引用格式

孙瑞卿, 许紫婷, 陈珠灵, 林佳丽. 分光光度法测定铬黑T解离常数实验设计. 大学化学[J], 2022, 37(12): 2112039-0 doi:10.3866/PKU.DXHX202112039

Sun Ruiqing. Experimental Design on the Determination of Dissociation Constants of Eriochrome Black T by Spectrophotometry. University Chemistry[J], 2022, 37(12): 2112039-0 doi:10.3866/PKU.DXHX202112039

铬黑T是大学化学实验常用的重要金属指示剂,可以与金属离子络合,形成与指示剂本身颜色不同的络合物,从而指示溶液中金属离子浓度的变化[1–3]。铬黑T的分子式为C20H12N3NaO7S (1-(1-羟基-2-萘基偶氮)-6-硝基-2-萘酚-4-磺酸钠盐),是一种有机弱酸盐,在水溶液中存在三级解离。常用的解离常数测定方法主要有电势滴定法[4, 5]、电导法[6, 7]、毛细管电泳法[8]、色谱法[9]、红外光谱法[10]、荧光光谱法[11]、紫外-可见分光光度法[12, 13]等。紫外-可见分光光度法适用于具有紫外-可见吸收特性的物质,实验方案简单高效。实验测定不同pH铬黑T溶液的紫外-可见吸收光谱,通过光谱特征分析,分段拟合pH与lg((A0 − A1)/(A1 − A2))的线性关系,从而计算得出铬黑T的解离常数pKa1、pKa2、pKa3。

1 仪器与试剂

1.1 仪器

紫外-可见光谱仪(日本岛津SHIMADZU,UV-2450),电子天平(德国赛多利斯,BSA124S,±0.0001 g),电子天平(YP6001,±0.1 g),酸度计(上海雷磁仪器厂,pHS-3C),移液枪(Thermo Lab Serv Junior,1–5 mL、100–1000 μL、10–100 μL),容量瓶(北京欣维尔,50.00 mL、250.00 mL)。

1.2 试剂

HCl、NaOH、NaH2PO4·2H2O、K2HPO4·3H2O、KCl、分析纯级(国药集团);铬黑T (天津市北辰方正试剂厂)。

1.3 溶液配制

(1) 铬黑T母液:准确称取0.1250 g铬黑T,用去离子水溶解,并定容于250.00 mL容量瓶,配成母液浓度1.084 × 10−3 mol·L−1。

(2) 缓冲溶液:配制pH 4.00、6.86和9.18的标准缓冲溶液,各250 mL。

(3) 其他溶液:配制0.1 mol·L−1 HCl,0.01 mol·L−1及1 mol·L−1 NaOH,0.2 mol·L−1 NaH2PO4,0.1 mol·L−1 K2HPO4,1 mol·L−1 KCl溶液,各100 mL。

(4) 铬黑T溶液:取29个50.00 mL的容量瓶,分别准确移取铬黑T母液4.00 mL;按不同的组合和添加量,分别加入0.1 mol·L−1 HCl、0.01 mol·L−1 NaOH、1 mol·L−1 NaOH、0.2 mol·L−1 NaH2PO4或0.1 mol·L−1 K2HPO4,调节每个溶液的pH;用KCl溶液调节离子强度;用去离子水定容到50.00 mL,配制成pH为2.09–12.98的系列溶液。

2 测定原理和实验过程

2.1 测定原理

在不同pH下,铬黑T溶液存在三级解离,解离过程见图 1。

图1

图1   铬黑T解离过程


铬黑T溶液具有紫外-可见吸收特性,一级、二级、三级解离的紫外-可见吸收光谱差异较大。在酸度较高的溶液中,铬黑T以三元弱酸形式存在,结构中含有一个磺酸基和二个羟基。

每级解离方程均可简化为:

当达到解离平衡时:

$ \mathrm{p} K_{\mathrm{a}}=\mathrm{pH}-\lg \frac{[\mathrm{D}]^{-}}{[\mathrm{HD}]}$

其中:Ka表示解离常数,[D]−、[HD]表示达到解离平衡时各自的浓度。

在酸度较高时,溶液中弱酸主要以HD形式存在,此时的吸光度设为A0;在碱度较高的溶液中,弱酸几乎完全解离为D−,此时吸光度设为A2;pH介于二者之间时,溶液中HD和D−共存,吸光度设为A1。根据Lambert-Beer定律[14],将公式(1)变换推导[1]可得:

$ \mathrm{pH}=\mathrm{p} K_{\mathrm{a}}+\lg \left(\frac{A_0-A_1}{A_1-A_2}\right)$

将配制的pH为2.09–12.98的29个铬黑T溶液样品(样品编号1–29),用紫外-可见分光光度计测定其吸收光谱,计算得到与pH对应的lg((A0 − A1)/(A1 − A2))系列数据,经回归拟合得出解离常数pKa。

2.2 实验过程

2.2.1 pH测定

以标准缓冲溶液(pH 4.00,6.86,9.18)为参比,用pHS-3C酸度计测定配制的29个铬黑T溶液样品的pH,见表 1。

表1   铬黑T溶液样品pH测定值

样品编号pH样品编号pH样品编号pH
12.09115.752110.84
22.82125.982211.26
33.18136.252311.58
43.55146.742411.76
53.90157.022511.98
64.22167.852612.27
74.50178.632712.58
84.77188.972812.81
94.981910.062912.98
105.542010.42

新窗口打开| 下载CSV


2.2.2 紫外-可见吸收光谱测定

首先,在1 cm石英比色皿中以去离子水为参比,在波长400–800 nm间扫描用于调节溶液pH的HCl、NaOH、NaH2PO4、K2HPO4和调节离子强度的KCl溶液,结果显示,这些溶液在扫描范围内均无吸收,不会对铬黑T溶液样品造成光谱干扰。然后,在同样条件下扫描29个铬黑T样品,得到紫外-可见吸收光谱,见图 2(a–c)。

图2

图2   不同pH的紫外-可见吸收光谱

电子版为彩图


3 实验结果分析

3.1 紫外-可见吸收光谱

由图 2可见,随着溶液pH的升高,紫外-可见吸收光谱的最大吸收峰先从516 nm红移到618 nm,之后再蓝移至455 nm,溶液的颜色从紫红到蓝色再到橙色,表明铬黑T在不同的pH条件下,其解离程度不同。随着pH升高,铬黑T逐级解离,每级解离的吸收光谱差异较大,因此可以用紫外-可见分光光度法测定铬黑T的各级解离常数。

根据图 2(a),pH 2.09和2.82的紫外-可见吸收曲线基本重合,最大吸收峰位于516 nm处,此时样品中铬黑T以分子型存在,用H3D表示。随着pH的升高,吸光度缓慢增加,铬黑T发生一级解离,pH 4.77和4.98的吸收曲线基本重合,至此,一级解离基本结束,此时铬黑T主要以H2D−型存在。在pH 2.82–4.77间,解离程度不同,H3D和H2D−共存。

图 2(b)表明,当pH > 4.98时,随着pH的升高,最大吸收峰位渐渐红移至618 nm处,吸光度迅速提高,铬黑T发生了二级解离。当pH为8.63时吸光度达到最大,与pH 8.97的吸收曲线重合,二级解离基本结束,此时铬黑T以HD2−型存在。在pH 4.98–8.63间,H2D−和HD2−共存。

图 2(c)显示,当pH > 8.97时,随着pH的升高,618 nm处的吸光度开始减小,吸收曲线发生了显著的变化,最大吸收峰从618 nm逐渐蓝移至455 nm处,455 nm处的吸光度逐渐增加,铬黑T发生了三级解离。由于pH > 13后的溶液不易调节,且pH > 12.81后的曲线变化校小,可以认为pH 12.98时,铬黑T基本完全解离,以D3−型存在。在pH 8.97–12.98间,HD2−和D3−共存。

3.2 解离常数计算

3.2.1 基础数据

以618 nm处吸光度为例来分析计算。根据前述分析,pH为2.09时,铬黑T以分子型存在,设此时的吸光度0.103为A0;pH为4.77时,一级解离基本完成,设此时的吸光度0.112为A2;pH为2.82、3.18、3.55、3.90、4.22、4.50时,吸光度为A1,由此可以计算一级解离的lg((A0 − A1)/(A1 − A2))系列值。pH为4.98时,开始二级解离,设此时的吸光度0.112为A0,pH为8.63时,二级解离基本完成,设此时的吸光度0.893为A2;pH为5.54、5.75、5.98、6.25、6.74、7.02、7.85时,吸光度为A1,由此可以计算二级解离的lg((A0 − A1)/(A1 − A2))系列值。pH为8.97时,开始三级解离,设此时的吸光度0.894为A0,pH为12.98时,三级解离基本完成,设此时的吸光度0.098为A2;pH为10.16、10.42、10.84、11.26、11.58、11.76、11.98、12.27、12.58、12.81时,吸光度为A1,由此可以计算三级解离的lg((A0 − A1)/(A1 − A2))系列值。计算结果详见表 2。

表2   618 nm处铬黑T溶液吸光度及计算

样品编号pHA(λ618 nm)$ \lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $样品编号pHA(λ618 nm)$ \lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $样品编号pHA(λ618 nm)$ \lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $
12.090.103115.750.193−0.9402110.840.693−0.470
22.820.104−0.903125.980.277−0.5702211.260.602−0.240
33.180.105−0.540136.250.37−0.3102311.580.4940.004
43.550.106−0.300146.740.6220.2752411.760.390.238
53.900.107−0.100157.020.7830.7852511.980.3010.465
64.220.1080.097167.850.892.4142612.270.1950.856
74.500.110.544178.630.8932712.580.1531.131
84.770.112188.970.8942812.810.1341.327
94.980.1121910.060.853−1.2702912.980.098
105.540.153−1.2602010.420.79−0.820

新窗口打开| 下载CSV


同理,以516 nm和455 nm处吸光度来分析计算各级解离的lg((A0 − A1)/(A1 − A2))系列值,结果详见表 3、表 4。

表3   516 nm处铬黑T溶液吸光度及计算

样品编号pHA(λ516 nm)$ \lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $样品编号pHA(λ516 nm)$ \lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $
12.090.27694.980.288
22.820.276105.540.289−1.890
33.180.277−1.040115.750.291−1.400
43.550.28−0.300125.980.303−0.630
53.900.2820136.250.316−0.260
64.220.2850.477146.740.3540.706
74.500.2871.041157.020.3651.585
84.770.288167.850.367

新窗口打开| 下载CSV


表4   455 nm处铬黑T溶液吸光度及计算

样品编号pHA(λ455 nm)$ \lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $样品编号pHA(λ455 nm)$ \lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $
167.850.2542311.580.375−0.100
178.630.2522411.760.4070.1
188.970.256−1.8402511.980.4470.371
1910.060.275−1.0402612.270.4670.533
2010.420.28−0.9502712.580.4930.814
2110.840.294−0.7502812.810.511.111
2211.260.333−0.3902912.980.53

新窗口打开| 下载CSV


3.2.2 拟合分析及解离常数

根据pH和相应的lg((A0 − A1)/(A1 − A2)),用ORIGIN进行拟合。以516 nm处一级解离为例,将pH 3.18、3.55、3.90、4.22、4.50与相应的lg((A0 − A1)/(A1 − A2))系列值−1.040、−0.300、0.000、0.477、1.041进行回归分析,得到拟合方程为:

其中:x为$\lg \left( {\frac{{{A_0} - {A_1}}}{{{A_1} - {A_2}}}} \right) $,y为pH。

拟合曲线见图 3。

图3

图3   测定pKa1的拟合曲线(516 nm)


同理,516 nm、618 nm、455 nm等处其他拟合曲线见图 4–图 8。

图4

图4   测定pKa1的拟合曲线(618 nm)


图5

图5   测定pKa2的拟合曲线(516 nm)


图6

图6   测定pKa2的拟合曲线(618 nm)


图7

图7   测定pKa3的拟合曲线(455 nm)


图8

图8   测定pKa3的拟合曲线(618 nm)


拟合方程在y轴上的截距即为pKa值,由此得出,铬黑T的解离常数pKa1为3.85 (516 nm)和3.94 (618 nm),pKa2为6.35 (516 nm)和6.41 (618 nm),pKa3为11.57 (455 nm)和11.43 (618 nm)。计算结果详见表 5。

表5   不同波长处拟合方程及测定的pKa值

波长拟合方程pKa值R2 (可决系数)
516 nmy = 0.661x + 3.85pKa1 = 3.850.979
618 nmy = 1.24x + 3.94pKa1 = 3.940.966
516 nmy = 0.441x + 6.35pKa2 = 6.350.987
618 nmy = 0.644x + 6.41pKa2 = 6.410.982
455 nmy = 1.29x + 11.57pKa3 = 11.570.980
618 nmy = 1.07x + 11.43pKa3 = 11.430.989

新窗口打开| 下载CSV


所有拟合方程可决系数R2均大于或等于0.966,表明pH与相应的lg((A0 − A1)/(A1 − A2))有较强的线性关系,方程拟合度均较好。

拟合计算得到的pKa值和相关文献值[1, 15]的相对偏差在−1.38% – 1.13%之间,详见表 6,说明实验测定结果的准确度较高。

表6   不同波长处测定的pKa值及准确度

文献值测定平均值相对偏差样品数n标准差SF检验
F表F计算
pKa1 = 3.9516 nm,pKa1 = 3.85−1.38%50.03426.262.29
618 nm,pKa1 = 3.941.13%60.0518
pKa2 = 6.4516 nm,pKa2 = 6.35−0.78%60.02724.952.29
618 nm,pKa2 = 6.410.16%70.0412
pKa3 = 11.5455 nm,pKa3 = 11.570.61%110.05113.142.79
618 nm,pKa3 = 11.43−0.61%100.0306

新窗口打开| 下载CSV


为确定在不同波长处测定的pKa值是否存在显著性差异,采用F检验法,对数据进行检验。以pKa1为例,根据化学数据速查手册[16],S大 = 0.0518 (n = 6),S小 = 0.0342 (n = 5),查表可知,在置信度为95%时,F表(5, 4)为6.26。

F计算 < F表,说明在516 nm和618 nm处测定的pKa1值无显著性差异。

同样对在不同波长处测定的pKa2和pKa3也进行了F检验,F计算均小于F表,详见表 6。

由此可见,通过紫外-可见分光光度法在不同波长处测定的解离常数无显著性差异,准确度较高。

4 结论

利用铬黑T溶液的光谱特性,通过配制一系列不同pH的铬黑T溶液,测定在不同解离程度下紫外-可见吸收光谱的吸光度,用ORIGIN软件进行拟合,推导出相应的数学模型,计算铬黑T水溶液的解离常数pKa1、pKa2、pKa3。实验表明,用紫外分光光度法测定铬黑T解离常数是可行的,且实验时无需配制准确浓度的铬黑T,仅要求每份溶液的浓度相等,实验方案简单,不同波长处测定的三级解离常数偏差小、一致性好、准确度高。具体教学实践中,可以将学生分为三组,同时分别测定pKa1、pKa2、pKa3,引导学生对结果进行分析讨论。用紫外分光光度法测定铬黑T解离常数,可以拓展、延伸大学本科化学实验教学内容,帮助学生深刻认识铬黑T特性和使用条件,理解酸碱多级解离过程,掌握分光光度法测定解离常数的基本原理,熟悉用ORIGIN处理实验数据、建立数学模型,培养学生综合分析和解决问题的能力。

参考文献

李克安. 分析化学教程, 北京: 北京大学出版社, 2017, 119

[本文引用: 3]

武汉大学. 分析化学实验, 第5版 北京: 高等教育出版社, 2018, 126

高绍康; 陈建中. 基础化学实验, 北京: 化学工业出版社, 2013, 636

[本文引用: 1]

李丽芳; 侯万国; 焦燕妮; 刘春霞. 物理化学学报, 2004, 20 (5), 459.

DOI:10.3866/PKU.WHXB20040503      [本文引用: 1]

徐洁; 侯万国; 周维芝; 台培东; 王文兴. 化学学报, 2007, 65 (13), 1191.

DOI:10.3321/j.issn:0567-7351.2007.13.001      [本文引用: 1]

陈玉焕; 张姝明; 王桂香; 张颖. 大学化学, 2016, 31 (6), 58.

URL     [本文引用: 1]

李晓亮; 张磊; 牛海军; 李光辉. 中国药业, 2020, 29 (15), 26.

URL     [本文引用: 1]

魏强; 杨歌; 管桦; 屈锋. 色谱, 2016, 35 (3), 332.

URL     [本文引用: 1]

王彩芬; 李卓; 王小波; 李海燕; 张继稳; 孙立新. 药学学报, 2015, 50 (9), 1167.

URL     [本文引用: 1]

窦彤彤; 张环环; 杨和丽; 张普敦. 光谱学与光谱分析, 2016, 36 (10), 87.

URL     [本文引用: 1]

陈明明; 盛良全; 蒋雪月; 刘昭第; 宋崇富. 光谱实验室, 2013, 30 (3), 1509.

URL     [本文引用: 1]

茹则妮萨·阿卜杜拉; 高惠静; 衣来努尔·吐依哄; 冉鑫; 高旖; 陈蓓; 王建华. 中国新药杂志, 2020, 29 (14), 1660.

URL     [本文引用: 1]

穆顺达; 郑国华; 宁成武; 屈勇. 药物分析杂志, 2018, 38 (6), 997.

URL     [本文引用: 1]

杨根元. 实用仪器分析, 第4版 北京: 北京大学出版社, 2010, 23

[本文引用: 1]

杭州大学化学系分析化学教研室. 分析化学手册(第二分册), 第2版 北京: 化学工业出版社, 1997, 551

[本文引用: 1]

李梦龙. 化学数据速查手册, 北京: 化学工业出版社, 2003.

[本文引用: 1]

/

〈 〉